Sign in →

EPIC ORDER CODE LAB1951 Syphilis IgG with Reflex, Enzyme Immunoassay, Serum

Additional Codes

SQ:  SYPHTM

MAYO:  SYPH1


Specimen Required


Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 1.5 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Useful For

Aid for the diagnosis of infection with Treponema pallidum using an algorithmic approach

 

Routine prenatal screening

 

This test is not offered as a screening or confirmatory test for blood donor specimens.

 

This test is not useful for diagnosis of congenital syphilis.

Reflex Tests

Test ID Reporting Name Available Separately Always Performed
RRPRS RPR Screen w/ Reflex to Titer, S No No
RTPPA Syphilis Ab, TP-PA, S Yes, (Order TPPA) No
RRPRQ RPR Titer, S No No

Testing Algorithm

If the syphilis IgG result is reactive or equivocal, then the rapid plasma reagin (RPR) screen will be performed at an additional charge.

 

If the RPR screen is positive, then the RPR titer will be performed at an additional charge.

 

If the RPR screen is negative, then syphilis antibody Treponema pallidum particle agglutination testing will be performed at an additional charge.

 

For more information see:

-Syphilis Serology Algorithm

-Meningitis/Encephalitis Panel Algorithm

Method Name

SYPH1: Enzyme Immunoassay (EIA)

RRPRS, RRPRQ: Flocculation/Agglutination

RTPPA: Particle Agglutination

Reporting Name

Syphilis IgG w/ Reflex, EIA, S

Specimen Type

Serum

Specimen Minimum Volume

1 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Frozen 14 days

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Heat-inactivated specimen Reject

Clinical Information

Syphilis is caused by infection with the spirochete Treponema pallidum subspecies pallidum. The infection is systemic, and the disease is characterized by periods of latency. These features, together with the fact that T pallidum cannot be isolated in culture, mean that serologic techniques play a major role in the diagnosis and follow-up of treatment for syphilis.

 

Historically, the serologic testing algorithm for syphilis included an initial nontreponemal screening test, such as the rapid plasma reagin (RPR) or the VDRL tests. Because these tests measure the host's immune response to nontreponemal antigens, they lack specificity. Therefore, a positive result by RPR or VDRL requires confirmation by a treponemal-specific test, such as the fluorescent treponemal antibody-absorption (FTA-ABS) or microhemagglutination (MHA-TP) assay. Although the FTA-ABS and MHA-TP assays are technically simple to perform, they are labor intensive and require subjective interpretation by testing personnel.

 

As an alternative to the traditional syphilis screening algorithm, many laboratories utilize the reverse syphilis screening algorithm. This algorithm starts with an automated treponemal assay to detect antibodies specific to T pallidum. If this screening assay is positive, the sample is reflexed for testing by RPR, which, if positive, is reported with a titer and is indicative of active or recent syphilis infection. If the RPR is negative, the sample is reflexed to a second treponemal assay, such as the T pallidum particle agglutination (TP-PA) assay. If the TP-PA is positive, this would indicate previously treated or late-stage syphilis infection. Alternatively, if the TP-PA is negative, the initial positive screen is interpreted as a false-positive result.

 

Syphilis screening at Mayo Clinic is performed using the reverse algorithm, which first tests sera for T pallidum specific IgG antibodies using an automated enzyme immunoassay. A positive treponemal test suggests infection with T pallidum but does not distinguish between recent, past, treated, or untreated infections. This is because treponemal tests may remain reactive for life, even following adequate therapy. Therefore, the results of a nontreponemal assay, such as RPR, are needed to provide information on a patient's disease state and history of therapy.(Table)

 

In some patients, the results of the treponemal screening test and RPR may be discordant (eg, syphilis IgG positive and RPR negative). To discriminate between a falsely reactive screening result and past syphilis, a second treponemal-specific antibody test is recommended using a method that is different from the initial screen test (eg, TP-PA).

 

In the setting of a positive syphilis IgG screening result and a negative RPR, a positive TP-PA result is consistent with either 1) past, successfully treated syphilis, 2) early syphilis with undetectable RPR, or 3) late/latent syphilis in patients who do not have a history of treatment for syphilis. Further historical evaluation is necessary to distinguish between these scenarios.(Table)

 

In the setting of a positive syphilis IgG screening result and a negative RPR, a negative TP-PA result is most consistent with a falsely reactive syphilis IgG screen.(Table) If syphilis remains clinically suspected, a second specimen should be submitted for testing.

 

Table. Interpretation and follow-up of reverse screening results:

Test and result

Patient history

Syphilis IgG antibody by EIA

RPR

TP-PA

Interpretation

Follow-up

Unknown history of syphilis

Nonreactive

NA

NA

No serologic evidence of syphilis

None, unless clinically indicated (eg, early/acute/ primary syphilis)

Unknown history of syphilis

Reactive

Reactive

NA

Untreated or recently treated syphilis

See Centers for Disease Control and Prevention treatment guidelines

Unknown history of syphilis

Reactive

Nonreactive

Nonreactive

Probable false-positive screening test

No follow-up testing, unless clinically indicated (eg, acute/primary syphilis)

Unknown history of syphilis

Reactive

Nonreactive

Reactive

Possible syphilis (eg, early or latent) or previously treated syphilis

Historical and clinical evaluation required

Unknown history of syphilis

Equivocal

NA

NA

NA

Unknown history of syphilis

Known history of syphilis

Reactive

Nonreactive

Reactive or NA

Past, successfully treated syphilis

None

EIA-enzyme immunoassay

NA-not applicable

RPR-rapid plasma reagin

TP-PA-T pallidum particle agglutination

Reference Values

SYPHILIS IgG SCREEN

Nonreactive

 

RAPID PLASMA REAGIN SCREEN

Negative

 

RAPID PLASMA REAGIN TITER

Negative

 

SYPHILIS ANTIBODY, Treponema pallidum-PARTICLE AGGLUTINATION

Negative

 

Reference values apply to all ages

Interpretation

Nonreactive:

No serologic evidence of infection to Treponema pallidum (syphilis). Repeat testing may be considered in patients with suspected acute or primary syphilis in 2 to 4 weeks.

 

Equivocal:

Rapid plasma reagin (RPR) has been ordered to help distinguish between infection with T pallidum (syphilis) versus a falsely reactive treponemal antibody result.

 

Reactive:

RPR has been ordered to help distinguish between infection with T pallidum (syphilis) versus a falsely reactive treponemal antibody result.

Clinical Reference

1. Centers for Disease Control and Prevention (CDC): Discordant results from reverse sequence syphilis screening-five laboratories, United States, 2006-2010. MMWR Morb Mortal Wkly Rep. 2011;60 Feb(5):133-137

2. Radolf JD, Tramont EC, Salazar JC: Syphilis (Treponema pallidum). In: Bennett JE, Dolin R, Blaser MJ, eds. Mandell, Douglas, and Bennett's Principles and Practice of Infectious Diseases. 9th ed. Elsevier; 2020:2865-2892

3. Binnicker MJ, Jespersen DJ, Rollins LO: Direct comparison of the traditional and reverse syphilis screening algorithms in a population with a low prevalence of syphilis. J Clin Microbiol. 2012: Jan;50(1):148-150

Method Description

Microtitration wells, coated with whole-cell sonicated Treponema pallidum (Nichols strain) antigens are incubated with serum specimens, which may contain specific antibodies to T pallidum. After incubation, unbound components in the test sample are washed away. IgG antibodies from the specimen that bound to T pallidum antigens are detected using monoclonal anti-human IgG secondary antibodies conjugated to horseradish peroxidase (HRP) during a second incubation period. Following a second wash cycle, the enzyme conjugate on bound secondary antibodies is detected following addition of TMB (tetramethylbenzidine). The enzymatic reaction is stopped using 1 N sulfuric acid. The assay is measured spectrophotometrically to indicate the presence or absence of IgG treponemal antibodies relative to a cut-off calibrator.(Package insert: CAPTIA Syphilis (T pallidum )-G. Trinity Biotech; 800-970-29 Rev H, 10/2013)

 

If the IgG result is equivocal or reactive, a rapid plasma reagin (RPR) screen is performed manually. If the RPR screen is positive, the RPR titer test is performed manually.

Day(s) Performed

Monday through Friday, Sunday

Report Available

Same day/1 to 4 days

Specimen Retention Time

14 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

86780-Syphilis IgG Screen

86592-Syphilis Rapid Plasma Reagin Screen (if appropriate)

86593-Rapid Plasma Reagin Titer (if appropriate)

86780-Syphilis Antibody by TP-PA (if appropriate)

LOINC Code Information

Test ID Test Order Name Order LOINC Value
SYPH1 Syphilis IgG w/ Reflex, EIA, S 47238-1

 

Result ID Test Result Name Result LOINC Value
SYPH1 Syphilis IgG w/ Reflex, EIA, S 47238-1