EPIC ORDER CODE LAB4988 Immunoglobulin Gene Rearrangement, Blood
Additional Codes
SQ: BCGRM
Reporting Name
Immunoglobulin Gene Rearrange, BUseful For
Determining whether a B-cell or plasma cell population is polyclonal or monoclonal using whole blood specimens
Identifying neoplastic cells as having B-cell or plasma cell differentiation
Monitoring for a persistent neoplasm by detecting an immunoglobulin gene rearrangement profile similar to one from a previous neoplastic specimen
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
Whole bloodShipping Instructions
Specimen must arrive within 7 days of collection.
Specimen Required
Container/Tube:
Preferred: Lavender top (EDTA)
Acceptable: Yellow top (ACD)
Specimen Volume: 4 mL
Collection Instructions:
1. Invert several times to mix blood.
2. Send whole blood specimen in original tube. Do not aliquot.
Specimen Minimum Volume
1 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Whole blood | Ambient (preferred) | 7 days | |
Refrigerated | 7 days |
Special Instructions
Reference Values
An interpretive report will be provided.
Day(s) Performed
Monday through Friday
Test Classification
This test was developed using an analyte specific reagent. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
81261-IGH (Immunoglobulin heavy chain locus) (eg, leukemias and lymphomas B-cell), gene rearrangement analysis to detect abnormal clonal populations; amplified methodology (eg. polymerase chain reaction)
81264-IGK (Immunoglobulin kappa light chain locus) (eg, leukemia and lymphoma, B-cell) gene rearrangement analysis, evaluation to detect abnormal clonal populations
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
BCGR | Immunoglobulin Gene Rearrange, B | 61113-7 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
18229 | Final Diagnosis: | 34574-4 |
608948 | Signing Pathologist | 19139-5 |
Clinical Information
The immunoglobulin genes (heavy, kappa, and lambda) are comprised of numerous, discontinuous coding segments. As B cells develop, the segments are rearranged such that each mature B cell and plasma cell has a unique rearrangement profile. Other cell types usually retain the unrearranged gene structures. Clonal expansion of any B cell or plasma cell will result in a population of cells that all contain an identical immunoglobulin gene rearrangement profile.
Reactive B-cell or plasma cell expansions are polyclonal, with each clone containing relatively few cells and no one clone predominating. Conversely, neoplastic clones are generally large such that the clonal cells are the predominant B cells or plasma cells present.
In the appropriate clinical and pathologic setting, detection of a prominent immunoglobulin gene rearrangement profile may be equated to the presence of a neoplastic B-cell or plasma cell clone.
Interpretation
An interpretive report will be provided.
The interpretation of the presence or absence of a predominant immunoglobulin gene rearrangement profile is sometimes subjective. These results must always be interpreted in the context of other clinicopathologic information to determine the significance of the result.
The detection of a clonal immunoglobulin gene rearrangement by this test is not synonymous with the presence of a B-cell or plasma cell neoplasm.
Clinical Reference
1. van Dongen JJ, Wolvers-Tettero IL: Analysis of immunoglobulin and T-cell receptor genes. Part II: Possibilities and limitations in the diagnosis and management of lymphoproliferative diseases and related disorders. Clin Chim Acta. 1991 April;198(1-2):93-174
2. Coad JE, Olson DJ, Lander TA, McGlennen RC: Molecular assessment of clonality in lymphoproliferative disorders: I. Immunoglobulin gene rearrangements. Mol Diagn. 1996 Dec;1(4):335-355
3. Kokovic I, Novakovic BJ, Novakovic S: Diagnostic value of immunoglobulin k light chain gene rearrangement analysis in B-cell lymphomas. Int J Oncol. 2015 Mar;46(3):953-962
Method Description
Genomic DNA is extracted from all specimens.
In the polymerase chain reaction (PCR) assay, a total of 34 upstream and 5 downstream primers are used (Invivoscribe IGH and IGK gene clonality reagents). The primers are designed to amplify fragments from all theoretical rearrangements of the immunoglobulin heavy and kappa light chain genes. Each unique rearrangement should produce PCR fragments of unique sizes. The primers cannot amplify anything if the immunoglobulin genes are not rearranged because the distance is too great. The primers are labeled with a fluorescent tag so that the PCR product can be detected. The PCR fragments are analyzed by capillary gel electrophoresis using a genetic analyzer for fragment size and amount.(Unpublished Mayo method)
Report Available
5 to 7 daysSpecimen Retention Time
Whole blood: 2 weeks; Extracted DNA: 3 monthsReject Due To
Gross hemolysis | Reject |
Moderately to severely clotted | Reject |
Method Name
Polymerase Chain Reaction (PCR)
Forms
1. Hematopathology Patient Information (T676)
2. If not ordering electronically, complete, print, and send a Hematopathology/Cytogenetics Test Request (T726) with the specimen.