EPIC ORDER CODE LAB501 Toxoplasma Antibody, IgG
Additional Codes
SQ : TOXOGG
COLLECTION
Light Green (Heparin Plasma Separator Tube) PREFERRED
SST (Serum Separator) PREFERRED
Green No Gel (Lithium Heparin)
Red (No Additive)
Lav (EDTA Plasma)
Collection Information:
Collect blood in a light green lithium heparin plasma separator tube or serum separator tube.
Add-on Requests -Requires Additional evaluation for acceptability.
Sample Volume Requirements:
Centrifuge and aliquot 0.5 mL serum or plasma into a plastic transport vial.
Minimum Sample Volume:
0.2 mL of serum or plasma (approximately 0.4 mL of whole blood based upon a normal patient hematocrit)
Unacceptable Conditions:
Heat inactivated serum, grossly lipemic or grossly hemolyzed samples
STABILITY
Refrigerated Stability:
3 weeks
Frozen Stability:
3 months
Ambient Stability:
3 days
PERFORMING LAB
Performed:
Monday-Friday 8:00a to 10:00p
Saturday-Sunday 9:00a to 5:00p
Analytical Time:
Same day, next run if repeat testing is necessary
Testing Laboratory:
Pathology Laboratory
Laboratory Section:
Core Laboratory
CPT Code
86777