EPIC ORDER CODE LAB5090 Centromere Antibodies

Additional Codes

SQ: CENTA

Performing Laboratory

Testing Laboratory: Pathology Laboratory

Laboratory Section: Core Laboratory

Reporting Name

Centromere Antibody

Method Name

Multiplex Flow Immunoassay

Specimen Required

Container/Tube Type: Red (No Additive)
SST (Serum Separator)

Collection Information: Collect 1.0 mL of blood. Transfer 0.5 mL of serum  to a transport vial.

Minimum Sample Volume: 0.25 mL

Remarks: Plasma samples from green and lavender top tubes are acceptable, but will route to a PROBL spot in the Sunquest Laboratory Information System.

Unacceptable Conditions: Grossly hemolyzed or lipemic specimens.

Specimen Minimum Volume

Minimum volume: 0.25 mL

Specimen Stability Information

Stability

Refrigerated Stability: 7 days

Frozen Stability: Indefinitely

Test Performed

Performed: Monday through Friday

Analytical Time: 1 day

Storage/Transport Information

1 mL serum at 2-8°C. (Min: 0.5 mL)