Sign in →

EPIC ORDER CODE LAB878 HIV-1 Ultra Sensitive RNA Quantitation by PCR

Additional Codes

Sunquest Order Code: HIV1UL

Alias: Acquired Immune Deficiency Syndrome (AIDS), AIDS (Acquired Immune Deficiency Syndrome), HIV (Human Immunodeficiency Virus), HIV-1 (Human Immunodeficiency Virus-1) RNA, Viral Load, HIV-1 PCR, HIV-1 Quantitation, PCR, Human Immunodeficiency Virus (HIV), Human Immunodeficiency Virus, PCR, PCR, HIV-1 Quantitation, Viral Load, Viral Load, HIV-1 RNA

SPECIMEN

Container/Tube Type: Lavender (EDTA)

Collection Information: Collect blood in a lavender (EDTA) tube.

Transport Information: Centrifuge and transfer 1.4 mL plasma to a plastic transport tube. Send refrigerated. 

Minimum Sample Volume: 1.0 mL of plasma (approximately 2.0 mL of whole blood based upon a normal patient hematocrit)

Remarks: Remove plasma from cells within 24 hours and transfer to a polypropylene tube at 2-8°C for transport.

Unacceptable Conditions: Serum and heparinized samples. ACD plasma will yield 15% lower test results than EDTA plasma.

SPECIMEN STABILITY

Stability Comments: Freeze thaw studies show specimen may be frozen and thawed up to 4 times without loss of HIV-1 RNA.

Stability

Refrigerated Stability: 

Whole blood in EDTA - 24 hours
Plasma - 6 days

Frozen Stability: 

Plasma - ≤ -18° C - 12 weeks
Plasma - ≤ -60° C - 6 months

Ambient Stability: Whole blood in EDTA - 24 hours

CPT

87536

TEST METHOD

Polymerase Chain Reaction

TESTING LABORATORY

Pathology Laboratory

Laboratory Section: Microbiology

ANALYTICAL TIME

Performed: Thursday

Analytical Time: Within 8 Days